  Datasheet File OCR Text:
  1 of 3 part numbering system series amp package quantity catalog number ordering number 0klk 1/8 10 0klk.125 0klk.125t 0klk 5 100 0klk005 0klk005.h specifcations voltage rating: 600 vac / 500 vdc amperage rating: 1 / 10 , 1 / 8 , 2 / 10 , 1 / 4 , 3 / 10 , 1 / 2 , 3 / 4 , 1, 1 1 / 2 , 2, 2 1 / 2 , 3, 3 1 / 2 , 4, 5, 6, 7, 8, 9,10, 12, 15, 20, 25, 30 interrupting ratings: ac: 100 ka 200 ka littelfuse self-certifed dc: 50 ka material: body: melamine / caps: copper alloy operating temperature: see rerating curve approvals: ul 248-14 listed (file: e10480) csa certifed ( file: lr29862) qpl (file: f60c) ce country of origin: mexico environmental: rohs compliant description fast-acting, high-interrupting capacity, current-limiting type fuse. especially suited for control circuits, street lighting, hid lighting, computers, and other applications without high in-rush currents. features/benefts ? ul approved ? 1/10 - 30 a ratings available ? 100,000 a interrupting rating applications ? control circuits ? street lighting, hid lighting ? computers dimensions inches (mm) recommended fuse holders littelfuse lfpsm dead-front series littelfuse leb series littelfuse l60030m series web resources download cad drawings and other technical information: littelfuse.com/klk klk series 10 x 38 fuses 600 vac/500 vdc ? 1 / 10 -30 a ? fast acting 0klk xxx h package quantity series amp code t = 10 h = 100 refer to amp code column in electrical specifications table 1 cartridge and axial lead fuses ?2015 littelfuse, inc. specifcations are subject to change without notice. revised: february 20, 2015 klk series ac > fast-acting type > klk series klk series, ac, fast-acting midget/5ag size fuse agency approvals agency agency file number ampere range e10480 .3a - 30a ? lr 29862 .3a - 30a qp l f60c electrical characteristics for series qp l fast-acting, high-interrupting capacity, current-limiting type fuse. especially suited for control circuits, street lighting, h.i.d. lighting, computers, and other applications without high in-rush currents. % of ampere rating ampere rating opening time 100% 0C30 until temp stabilizes 135% 0C30 1 hours, maximum 200% 0C30 2 minutes, maximum. ordering number amp rating (a) max voltage rating (v) interrupting rating nominal cold resistance (ohms) agency approvals qpl klk .100 .100 600 100,000 amperes (capable of 200,000) at 600vac. 85.5 x x x klk .125 .125 65.0 x x x klk .200 .200 30.9 x x x klk .250 .250 22.0 x x x klk .300 .300 16.2 x x x klk .500 .500 7.99 x x x klk .750 .750 .398 x x x klk 001 1 .249 x x x klk 01.5 1. 5 .132 x x x klk 002 2 .129 x x x klk 02.5 2.5 .0989 x x x klk 003 3 .0773 x x x klk 03.5 3.5 .0613 x x x klk 004 4 .0511 x x x klk 005 5 .0357 x x x klk 006 6 .0261 x x x klk 007 7 .0205 x x x klk 008 8 .0194 x x x klk 009 9 .0166 x x x klk 010 10 .0128 x x x klk 012 12 .0103 x x x klk 015 15 .0073 x x x klk 020 20 .00421 x x x klk 025 25 .00329 x x x klk 030 30 .00267 x x x electrical specifcations by item ? temperature rerating curve product characteristics military type f60c interrupting rating 200,000 amperes at 500vac 150,000 amperes at 500vdc 38.1 (1.50") 10.31 (.406") dimensions description -60c -40c -20c 0c 20c 40c 60c 80c 100c 120c 140c -76f -40f -4f 32f 68f 104f 140f 176f 212f 248f 284f ambient tempera ture 60 40 20 0 percent of upra ting 0 20 40 60 per cent of dow nra tin g temperature derating curve (temperature of air immediately surrounding fuse) littelfuse.com ? 2015 littelfuse powr-gard ? products rev: 082715 powr-gard ? fuse datasheet
2 of 3 amp rating amp code catalog number ordering number voltage interrupting rating ( k a) upc weight lb (g) agency approvals ac dc ac dc ul csa 1 / 10 .100 0klk 1 / 10 0klk.100t 600 500 100 50 07945825011 .013 (5.90) ? ? 1 / 8 .125 0klk 1 / 8 0klk.125t 600 500 100 50 07945825012 .013 (5.90) ? ? 2 / 10 .20 0klk 2 / 10 0klk.200t 600 500 100 50 07945825018 .013 (5.90) ? ? 1 / 4 .250 0klk 1 / 4 0klk.250t 600 500 100 50 07945825019 .013 (5.90) ? ? 3 / 10 .300 0klk 3 / 10 0klk.300t 600 500 100 50 07945825020 .013 (5.90) ? ? 1 / 2 .500 0klk ? 0klk.500t 600 500 100 50 07945825024 .013 (5.90) ? ? 3 / 4 .750 0klk 3 / 4 0klk.750t 600 500 100 50 07945825029 .013 (5.90) ? ? 1 001. 0klk 1 0klk001.t 600 500 100 50 07945825031 .013 (5.90) ? ? 1 1 / 2 01.5 0klk 1 1 / 2 0klk01.5t 600 500 100 50 07945825037 .013 (5.90) ? ? 2 002. 0klk 2 0klk002.t 600 500 100 50 07945825041 .017 (7.71) ? ? 2 1 / 2 02.5 0klk 2 1 / 2 0klk02.5t 600 500 100 50 07945825043 .017 (7.71) ? ? 3 003. 0klk 3 0klk003.t 600 500 100 50 07945825047 .017 (7.71) ? ? 3 1 / 2 03.5 0klk 3 1 / 2 0klk03.5t 600 500 100 50 07945825048 .017 (7.71) ? ? 4 004. 0klk 4 0klk004.t 600 500 100 50 07945825053 .017 (7.71) ? ? 5 005. 0klk 5 0klk005.t 600 500 100 50 07945825055 .017 (7.71) ? ? 6 006. 0klk 6 0klk006.t 600 500 100 50 07945825058 .017 (7.71) ? ? 7 0 07. 0klk 7 0k lk0 07.t 600 500 100 50 07945825061 .017 (7.71) ? ? 8 008. 0klk 8 0klk008.t 600 500 100 50 07945825063 .017 (7.71) ? ? 9 009. 0klk 9 0klk009.t 600 500 100 50 07945825064 .017 (7.71) ? ? 10 010. 0klk 10 0klk010.t 600 500 100 50 07945825065 .017 (7.71) ? ? 12 012. 0klk 12 0klk012.t 600 500 100 50 07945825067 .017 (7.71) ? ? 15 015. 0klk 15 0klk015.t 600 500 100 50 07945825068 .017 (7.71) ? ? 20 020. 0klk 20 0klk020.t 600 500 100 50 07945825071 .017 (7.71) ? ? 25 025. 0klk 25 0klk025.t 600 500 100 50 07945825072 .017 (7.71) ? ? 30 030. 0klk 30 0klk030.t 600 500 100 50 07945825073 .017 (7.71) ? ? klk series 10 x 38 fuses amperage rating opening time (minutes) 100% of amp rating per ul 135% of amp rating per ul 200% of amp rating per ul 1 / 10 -30 temperature stabilization 60 max 2 max electrical specifcation C agency requirements ordering information littelfuse.com ? 2015 littelfuse powr-gard ? products rev: 082715 powr-gard ? fuse datasheet
3 of 3 1000 900 800 700 600 500 1000 900 800 700 600 500 100 90 80 70 60 50 40 30 20 10 9 8 7 6 5 4 3 2 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 500 400 300 200 100 90 80 70 500 400 300 200 100 90 80 70 70 60 50 40 30 20 10 70 60 50 40 30 20 10 - 1/10a - 1/8a - 2/10a 1/4a 10 9 8 7 6 5 4 3 2 10 9 8 7 6 5 4 3 2 - 1/4a - 3/10a - 1/2a - 3/4a - 1a - 1-1/2a - 2a time ? in ?seconds 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0 .2 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0 .2 - 2-1/2a 0 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0.02 0.01 100 90 80 70 60 50 40 30 20 10 9 8 7 6 5 4 3 2 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 current? in ?amperes basis for data: test voltage: time constant/power factor: fuse catalog number: drawn by: date: revision: drawing no.: sheet time current characteristic curves littelfuse,? inc. chicago, ? il. ? usa lll 11/19/08 a 2 of 4 fcc01 - klk klk 1/10a - 30a - data generated in excel - time ? current characteristic  curves fcc01 - klk 1000 900 800 700 600 1000 900 800 700 600 1000 900 800 700 600 500 400 300 200 100 90 80 70 60 50 40 30 20 10 9 8 7 6 5 4 3 2 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 500 400 300 200 100 90 80 500 400 300 200 100 90 80 - 15a - 20a - 25a - 30a 70 60 50 40 30 20 70 60 50 40 30 20 10 9 8 7 6 5 4 3 2 10 9 8 7 6 5 4 3 2 time ? in ?seconds 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 02 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 02 0 . 2 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0 . 2 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.03 0.02 0.01 0.03 0.02 0.01 1000 900 800 700 600 500 400 300 200 100 90 80 70 60 50 40 30 20 10 9 8 7 6 5 4 3 2 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 current? in ?amperes basis for data: test voltage: time constant/power factor: fuse catalog number: drawn by: date: revision: drawing no.: sheet time current characteristic curves littelfuse,? inc. chicago, ? il. ? usa lll 11/19/08 a 4 of 4 fcc01 klk klk 1/10a - 30a - data generated in excel - time ? current characteristic  curves fcc01 - klk 1000 900 800 700 600 1000 900 800 700 600 1000 900 800 700 600 500 400 300 200 100 90 80 70 60 50 40 30 20 10 9 8 7 6 5 4 3 2 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 500 400 300 200 100 90 80 500 400 300 200 100 90 80 70 60 50 40 30 20 70 60 50 40 30 20 10 9 8 7 6 5 4 3 2 10 9 8 7 6 5 4 3 2 - 3a - 3-1/2a - 4a time ? in ?seconds 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 02 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 02 - 5a - 6a - 8a - 9a - 10a - 12a 0 . 2 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0 . 2 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.03 0.02 0.01 0.03 0.02 0.01 1000 900 800 700 600 500 400 300 200 100 90 80 70 60 50 40 30 20 10 9 8 7 6 5 4 3 2 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 current? in ?amperes basis for data: test voltage: time constant/power factor: fuse catalog number: drawn by: date: revision: drawing no.: sheet time current characteristic curves littelfuse,? inc. chicago, ? il. ? usa lll 11/19/08 a 3 of 4 fcc01 - klk klk 1/10a - 30a - data generated in excel - time ? current characteristic  curves fcc01 - klk klk series 10 x 38 fuses time current curve ( 1 / 10 - 2 1 / 2 a) time current curve (15 - 30 a) time current curve (3 - 12 a) littelfuse.com ? 2015 littelfuse powr-gard ? products rev: 082715 powr-gard ? fuse datasheet


▲Up To Search▲   

 
Price & Availability of 0KLK010T

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X